Series DS-1 Dry-Type Sprinklers

Pendent, Upright, and Horizontal Sidewall

Standard Response, Standard Coverage, K-factor=5.6K

Features:

  • Standard coverage
  • All hazards (light hazards, horizontal sidewall)
  • Lengths up to 48″ (1220 mm)
  • Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing conditions, or the sprinkler system is seasonally drained
  • Special assembly provides a seal at the main pipe to prevent water from entering the assembly until the sprinkler operates
  • Designed for use in applications requiring dry sprinklers, or where building construction or aesthetic considerations make the installation of dry horizontal sidewall sprinklers more desirable than the dry pendent type

Hazard: All,Light Hazard/Ordinary Hazard

Temperature: 135, 155, 175, 200,

286, 360

Thread: 1″

Approval: UL, C-UL, FM, NYC, LPCB,

CE, VdS

Response: Standard Response

SIN Numbers: TY3155,TY3255,TY3355

Wrench: Pipe Wrench

Wrench [Recessed]: ,W7

Series DS-1 Dry-Type Sprinklers

Pendent, Upright, and Horizontal Sidewall

Quick Response, Standard Coverage, K-factor=5.6K

Features:

  • Light hazard/Ordinary hazard
  • Lengths to 48″ (1220 mm)
  • Designed for use in applications where sprinklers and/or connecting piping may be exposed to freezing  conditions, or the sprinkler system is seasonally drained
  • Special assembly provides a seal at the main pipe to prevent water from entering the assembly until the sprinkler operates
  • Designed for use in applications requiring dry sprinklers, or where building construction or aesthetic considerations make the installation of dry horizontal sidewall sprinklers more desirable than the dry pendent type

Hazard: All,Light Hazard/Ordinary Hazard

Temperature: 135, 155, 175, 200, 286

Thread: 3/4″,1″

Approval: UL, C-UL, FM, NYC

Response: Quick Response

SIN Numbers: TY3935,TY3735,TY3135,TY3235,TY3335

Wrench: Pipe Wrench

Wrench [Recessed]: W7,

Model ESFR-17

Dry Type Pendent Sprinklers

Early Suppression Fast Response 16.8 K-factor

Features:

  • Early Suppression, Fast Response (ESFR)
  • The Model ESFR-17 Dry Type Sprinklers are primarily used for ceiling only sprinkler protection and used to protect solid piled, palletized, and rack storage that is subject to freezing temperatures
  • Suppression mode sprinklers that are especially advantageous as a means of eliminating in-rack sprinklers when protecting high-piled box-in-box refrigerated storage areas
  • The drop between the inlet and sprinkler remains dry until the sprinkler operates, allowing for a pendent sprinkler installation on a wet pipe sprinkler system where the dry drop and sprinkler are located in an area subjected to freezing temperatures
  • Eliminates in-rack sprinklers for box-in-box applications
  • The Model ESFR-17 Dry Type Pendent Sprinkler is FM Approved and has successfully undergone full-scale fire testing at FM Global, when used in conformance with applicable FM Global Property Loss Prevention Data Sheets.
  • Less costly to install and maintain than pre-action or antifreeze systems


Hazard: Storage

Temperature: 165, 212

Thread: 1-1/4″

Approval: UL, FM

Response: FR

SIN Numbers: TY7229

Wrench: W26